Bernville Quality Fuels, Inc. has a Customized Home Heating Security Plan that will save you money and energy all year for warm air furnaces, hot water boilers, steam boilers, and hot water heaters. One plan has the home heating service coverage that meets your needs.

Plan A - Basic Oil Service
Residential Oil Furnace, Boiler or Hot Water Heater Inspection and Tune-up
Residential home furnaces, boilers - Plan A
Modular home furnaces, oil fired hot water heaters - Plan A

  1. Thoroughly vacuum, clean heater as needed, vent pipe, base of chimney and combustion chamber (if accessible)
  2. Replace nozzle, if necessary
  3. Clean and adjust electrodes and high tension leads
  4. Check fuel pump and pump strainer, check vacuum and pressure
  5. Check transformer ignition or flame failure
  6. Complete draft test and adjust draft regulator accordingly
  7. Inspect oil lines for possible leaks
  8. Oil motors, bearings, and fan bearings
  9. Change oil filters and air filters
  10. Perform Bacharach combustion test and adjust for peak performance
  11. Check all safety controls for lock-out timing
  12. Check stove pipe for cracks and wear

Plan B - Basic Gas Service
Residential Propane or Natural Gas Furnace, Boiler, Separate Hot Water Heater Inspection and Tune-Up
Residential gas furnaces and boilers
Residential gas water heaters

  1. Thoroughly vacuum, clean heater as needed, vent pipe, base of chimney and combustion chamber (if accessible)
  2. Inspect thermocouple, pilot orifice, or glow coil
  3. Clean and adjust air tubes, burners and inducers
  4. Check vacuum and pressures
  5. Check for ignition or flame failure
  6. Inspect inside gas lines for leaks and corrosion
  7. Oil motors and blower fan bearing
  8. Change air filters
  9. Check efficiency and adjust for peak performance
  10. Check all safety controls for lock-out timing

Conditions for Plan A & B

  1. Tune-ups requiring over 2.5 hours (Plan B 2 hours) will be billed on a time and materials basis
  2. Non-scheduled tune-ups will be billed at prevailing hourly rates and materials
  3. Parts will be billed at prevailing rates at time of tune-up
  4. Emergency service or additional work will be performed at prevailing hourly rate
  5. (Plan B only) Only customers purchasing liquid products or heating and cooling equipment qualify for tune-ups and emergency service for gas equipment

Plan C - Premium Heating Security Plan
Premium Heating Security Plan for Oil and Propane Systems Only
Hot water/steam boilers
Hot air furnaces
Hot water heaters

Addresses the worry of heating system breakdowns when you least expect them. Includes the following services:

  • All services under Plan A or Plan B
  • Provides “no charge” for labor or parts listed below 24 hours a day - seven days a week. After hours calls will be run on a strictly emergency/no heat basis
  • Bernville Quality Fuels, Inc. will repair or replace defective parts on your heating system as listed below for one (1) year from date of contract
1. Air filters one (1) set disposable type only
28. Fuel filter replacement cartridge
2. Aquastat
29. Heater gas controls
3. Automatic gas valve
30. Hot water circulator
4. Blow down valve
31. Ignition leads
5. Blower belts
32. Igniters
6. Blower motor (up to 3/4 HP)
33. Induced fan pressure switch
7. Blower control relays
34. Limit controls
8. Burner coupling
35. Low water cut-off
9. Burner end cone
36. Low water cut-off float
10. Burner blast tube
37. Low water cut-off switch
11. Burner fan
38. Module controls
12. Burner gas control elements
39. Nozzle
13. Burner manifold
40. Nozzle line
14. Burner motor
41. Oil burner emergency switches
15. Burner transformer
42. Pilot burner, orifice, tubing & valve
16. Cad cell assembly
43. Porcelains
17. ***Circulator motor (1 primary heating zone)
44. Pressure regulators
18. Circulator coupling
45. Primary safety control
19. Circulator relay
46. Pump strainers
20. Draft hood
47. Relays
21. Draft inducer (only gas)
48. Safety pilot
22. Draft regulator & vent pipe
49. Spill switch
23. Electrodes
50. Steam pressure controls
24. Factory wiring
51. Thermocouples
25. Fan & limit controls
52. **Thermostat standard (1 per year)
26. Fan door switch
53. Transformers
27. Fuel pump
54. Venturi tube

**Plain, not clock type, and heating only
***Circulator or Bearing Assembly will not be covered unless installed with shut-off flanges.
For additional protection add additional costs for each additional circulator motor and controls. Add this amount to your Premium Heating Security Plan.

Plans are available for commercial boilers or furnaces firing rate 2.75 gallons per hour or higher. Contract prices are based on size and number of units. Coverage based on regular Residential Plans.

Plan D - Supreme Heating Security Plan
Supreme Heating Security Plan for Oil & Propane Systems Only
Oil-propane hot water/steam system
Oil-propane forced hot air system

Provides coverage for total peace of mind.
Provides coverage for additional equipment and parts not covered under Plan C.

  • Includes all services under Plan A
  • Provides “no charge” for labor or parts 24 hours a day - seven days a week for every part of your heating unit except as listed below
1. Heat exchanger or boiler shell
6. Indirect water heater and controls, unless specified for an additional cost
2. Hot water coil
7. Oil tanks, lines covered to tank or wall, if underground (allowance toward replacement tank)
3. Air conditioner parts
8. Each additional circulator or zone valve and controls additional cost (this plan covers circulators and bearing assembly with or without shut-offs)
4. Humidifier parts and service, unless specified for an additional cost
9. Heating distribution units (radiators, baseboard radiation, piping, ductwork, etc.)
5. Electronic air cleaner or non-electronic air cleaner, unless specified for an additional cost
10. Domestic hot water coil and tempering valve


Plans are available for commercial boilers or furnaces firing rate 2.75 gallons per hour or higher. Contract prices are based on size and number of units.

To review the terms and conditions click here.

 